    Red Advanced Gas Extinguishing System 4 Zone For Fire Suppression Fire Fighting

    Ask Lasest Price
    Brand Name : XHA
    Model Number : XHAGC1004
    Certification : CE
    Price : negotiable
    Payment Terms : T/T,Western Union
    Supply Ability : 500pcs/month
    Delivery Time : 3 Working days
    • Product Details
    • Company Profile

    Red Advanced Gas Extinguishing System 4 Zone For Fire Suppression Fire Fighting

    Advanced Gas Extinghuishing System For Fire Suppression Fire Fighting


    Red Advanced Gas Extinguishing System 4 Zone For Fire Suppression Fire Fighting



    Introduction

    A gas extinguishing control panel is the central command and control unit for a gas-based fire suppression system. It is responsible for monitoring the fire detection devices, activating the extinguishing agent release, and coordinating the overall fire safety operation.


    Key components and functions of a gas extinguishing control panel include:


    Fire Detection Monitoring:
    The control panel receives input signals from smoke detectors, heat detectors, or other fire alarm sensors installed in the protected area.
    It continuously monitors the status of these detection devices to identify the presence of a fire hazard.
    The panel is programmed with specific logic and algorithms to determine when a fire event has occurred based on the detection inputs.
    Extinguishing Agent Release Control:
    Upon detecting a fire, the control panel initiates the release of the gaseous extinguishing agent, such as carbon dioxide (CO2), clean agents, or inert gases.
    It coordinates the opening of valves, the discharge of the extinguishant from storage cylinders or tanks, and the activation of any associated warning devices.
    The panel ensures the controlled and timed discharge of the extinguishing agent to effectively suppress the fire.
    System Monitoring and Status Display:
    The control panel provides a comprehensive overview of the fire suppression system's status, including any faults, troubles, or activations.
    It features user-friendly interfaces, such as LCD screens or touchpanels, to display real-time information about the system's condition.
    Indicator lights, audible alarms, and other visual cues help operators quickly identify the system's status.
    Manual Controls and Interfaces:
    The control panel allows authorized personnel to manually initiate the extinguishing system, silence alarms, and reset the system after an activation.
    It may include keypad interfaces, push-buttons, or other input devices for manual control and system interaction.
    The panel may also provide interfaces for integration with building management systems, alarm monitoring services, or other safety and security systems.
    Power Supply and Backup:
    The control panel is typically powered by the building's electrical system, with backup battery power to ensure continuous operation in the event of a power failure.
    Redundancy measures, such as dual power supplies or battery backup systems, help maintain the panel's functionality during emergencies.


    Gas extinguishing control panels are designed to be robust, reliable, and compliant with relevant fire safety standards and regulations. They play a crucial role in the effective management and operation of gas-based fire suppression systems, ensuring the protection of lives, property, and critical assets.


    Specification

    Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System

    Connection Diagram


    Red Advanced Gas Extinguishing System 4 Zone For Fire Suppression Fire Fighting


    Product Range

    Conventional Fire Alarm System
    Addressable fire alarm system
    Gas Extinguishing control system
    Beam Detector
    4 wire smoke detectors with relay output.
    2 wire Conventional smoke and heat detectors
    Explosion-proof flame detector for fire alarm system
    Standalone smoke detectors and combustable gas detector




    Service

    1. OEM &ODM service.
    2. Provide technical support and after-sale service.
    3. 1 year warranty.
    4. Normally 15 working days lead time.

    5. Welcome sample order.



    Quality Red Advanced Gas Extinguishing System 4 Zone For Fire Suppression Fire Fighting for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Xinhe'an Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)