Conventional Smoke Detector For Fire Detection And Alarm In Conventional Fire Alarm System

Shenzhen Xinhe'an Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Conventional Smoke Detector For Fire Detection And Alarm In Conventional Fire Alarm System from wholesalers
     
    Buy cheap Conventional Smoke Detector For Fire Detection And Alarm In Conventional Fire Alarm System from wholesalers
    • Buy cheap Conventional Smoke Detector For Fire Detection And Alarm In Conventional Fire Alarm System from wholesalers
    • Buy cheap Conventional Smoke Detector For Fire Detection And Alarm In Conventional Fire Alarm System from wholesalers
    • Buy cheap Conventional Smoke Detector For Fire Detection And Alarm In Conventional Fire Alarm System from wholesalers

    Conventional Smoke Detector For Fire Detection And Alarm In Conventional Fire Alarm System

    Ask Lasest Price
    Brand Name : XHA
    Model Number : XHA8015
    Certification : CE
    Price : negotiable
    Payment Terms : T/T, Western Union
    Supply Ability : 10000PCS/Month
    Delivery Time : 3 Working days
    • Product Details
    • Company Profile

    Conventional Smoke Detector For Fire Detection And Alarm In Conventional Fire Alarm System

    2 Wire Smoke Alarm For Conventional Detection Alarm System


    Conventional Smoke Detector For Fire Detection And Alarm In Conventional Fire Alarm System

    Introduction

    The primary purpose of a conventional smoke detector is to provide early warning of a potential fire by detecting the presence of smoke and triggering an audible alarm to alert occupants. This allows people to evacuate the area and call emergency services if necessary. it can be compartible with other brand conventional panel.


    The main functions of a conventional smoke detector are:

    Smoke Detection:
    The smoke detector uses photoelectric sensor to detect the presence of smoke particles in the air.
    The sensor reacts to the changes in the air caused by smoke, triggering the alarm.


    Alarm Activation:
    When smoke is detected, the smoke detector activates an audible alarm, such as a loud beeping or buzzing sound.
    The alarm is intended to alert occupants to the potential fire hazard, prompting them to evacuate the area.


    Power Supply:
    Conventional smoke detectors can be powered by a hardwired connection to the building's electrical system.

    Testing and Maintenance:
    Smoke detectors require regular testing to ensure they are functioning correctly.
    Periodic cleaning is also necessary to maintain their reliability.




    Parameters

    Product NameSmoke DetectorRated operational voltage9 to 28VDC Volts Non-polarized
    Adjustable Sensitivity1.06±.26%FTStatic current≤60µA @ 24 VDC
    Alarm current30mA @ 24 VDCWork temperature-10°C~+50°C
    CertificationCEHumidity≤95%.
    Size103*103*55mmWeight105g

    Installation



    INSTALLATION
    NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
    NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct.

    Remove power from initiating-device circuits before installing detectors.
    1. Wire the sensor base per the wiring diagram, Figure 1.
    2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place.
    3. After all sensors have been installed, apply power to the control unit.
    4. Test the sensor(s) as described in the TESTING section of this manual.
    5. Notify the proper authorities that the system is in operation.

    Warning:Forbid connect 24VDC directly without current-limiting resistance. Otherwise, the detector would be burnt out.


    Conventional Smoke Detector For Fire Detection And Alarm In Conventional Fire Alarm System


    Conventional Smoke Detector For Fire Detection And Alarm In Conventional Fire Alarm System


    Product range

    Conventional Fire Alarm System
    Addressable fire alarm system
    Gas Extinguishing control system
    Beam Detector
    4 wire smoke detectors with relay output.
    2 wire Conventional smoke and heat detectors
    Explosion-proof flame detector for fire alarm system
    Standalone smoke detectors and combustable gas detector




    Service

    1. OEM &ODM service.
    2. Provide technical support and after-sale service.
    3. 1 year warranty.
    4. Normally 15 working days lead time.

    5. Welcome sample order.




    Quality Conventional Smoke Detector For Fire Detection And Alarm In Conventional Fire Alarm System for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Xinhe'an Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)