Sign In | Join Free | My himfr.com
Home > Conventional Fire Alarm System >

Wired Conventional Fire Alarm System with Heat Detector for Building Protection System

Shenzhen Xinhe'an Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Wired Conventional Fire Alarm System with Heat Detector for Building Protection System from wholesalers
     
    Buy cheap Wired Conventional Fire Alarm System with Heat Detector for Building Protection System from wholesalers
    • Buy cheap Wired Conventional Fire Alarm System with Heat Detector for Building Protection System from wholesalers
    • Buy cheap Wired Conventional Fire Alarm System with Heat Detector for Building Protection System from wholesalers
    • Buy cheap Wired Conventional Fire Alarm System with Heat Detector for Building Protection System from wholesalers

    Wired Conventional Fire Alarm System with Heat Detector for Building Protection System

    Ask Lasest Price
    Brand Name : XHA
    Model Number : XHA8025
    Certification : CE
    Price : negotiable
    Payment Terms : T/T, Western Union
    Supply Ability : 10000PCS/Month
    Delivery Time : 3 Working days
    • Product Details
    • Company Profile

    Wired Conventional Fire Alarm System with Heat Detector for Building Protection System

    Conventional Heat Detector For Fire Alarm Fire Detection System In Building



    Wired Conventional Fire Alarm System with Heat Detector for Building Protection System

    Introduction


    This Heat detector consists of the following key components:

    Sensing Element:
    The sensing element is the core component that detects changes in temperature.
    It can use either a fixed temperature or a rate-of-rise principle to detect heat.
    Fixed temperature detectors activate the alarm when the temperature reaches a predetermined threshold.
    Rate-of-rise detectors activate the alarm when the temperature rises at a rapid rate, indicating a potential fire.


    Alarm Horn/Sounder:
    When the sensing element detects a rise in temperature, the heat detector activates a loud audible alarm, typically a high-decibel beeping or buzzing sound.
    The alarm is intended to wake up and alert occupants to the presence of a heat source, prompting them to evacuate the area.


    Power Source:
    Conventional heat detectors can be powered by a hardwired connection to the building's electrical system.

    Status Indicators:
    Heat detectors often have visual status indicators, such as LED lights, to provide feedback on the device's operational status.
    These indicators can signal issues like low battery, sensor malfunctions, or normal operation.


    Mounting:
    Conventional heat detectors are typically mounted on the ceiling or high on walls, as heat rises and accumulates at the ceiling level.
    The mounting hardware allows for easy installation and replacement of the detector as needed.


    Parameters

    Product NameHeat DetectorRated operational voltage9 to 28VDC Volts
    Wired2 Wired, Non-polarizedStatic current≤80µA @ 24 VDC
    Alarm current20mA @ 24 VDCWork temperature-10°C~+50°C
    CertificationCEHumidity≤95%.
    Size103*103*55mmWeight105 g

    Feature


    Conventional Smoke Detector, Operates by Advanced MCU Expert Algorithm Software.

    SMD circuit board design-satisfactory quality and reliability guaranteed

    They work perfectly with all conventional intelligent fire control panels
    Key Specifications/Special Features
    Advanced MCU Expert Algorithm Software.
    Durable sensor head, no need for replacement

    Easy installation and maintenance


    Installation



    INSTALLATION
    NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
    NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct.

    Remove power from initiating-device circuits before installing detectors.
    1. Wire the sensor base per the wiring diagram, Figure 1.
    2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place.
    3. After all sensors have been installed, apply power to the control unit.
    4. Test the sensor(s) as described in the TESTING section of this manual.
    5. Notify the proper authorities that the system is in operation.

    Warning:Forbid connect 24VDC directly without current-limiting resistance. Otherwise, the detector would be burnt out.


    Wired Conventional Fire Alarm System with Heat Detector for Building Protection System


    Wired Conventional Fire Alarm System with Heat Detector for Building Protection System


    Product range

    Conventional Fire Alarm System
    Addressable fire alarm system
    Gas Extinguishing control system
    Beam Detector
    4 wire smoke detectors with relay output.
    2 wire Conventional smoke and heat detectors
    Explosion-proof flame detector for fire alarm system
    Standalone smoke detectors and combustable gas detector




    Service

    1. OEM &ODM service.
    2. Provide technical support and after-sale service.
    3. 1 year warranty.
    4. Normally 15 working days lead time.

    5. Welcome sample order.




    Quality Wired Conventional Fire Alarm System with Heat Detector for Building Protection System for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Xinhe'an Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)